D663-4002

commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field including equipment management information Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage systems Module identification with production operating parameters c complete self-diagnosis Compact and robust design Front Panel Wiring…

Details

D636-225-0000

powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control The scheme can be realized by the combination of these function blocks. The function blocks provided by the system mainly include the following categories: o Analog processing o digital processing loop regulation Logical sequence control c logic operation Monitoring…

Details

D634-538A

communication Industrial” system uses international standard industrial bus. Field controller supports Profibus, FF, ModBus, Can, etc. International standard fieldbus, Profibus is the most widely used open fieldbus international standard in the world, divided into FMS, DP and PA Level 3, DP communication rate can be as high as 12Mb. Profibus is used to connect intelligent…

Details

D634-1063

configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram (LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions Algorithm library for energy blocks and a basic library with more than 200 graphic symbols and…

Details

D634-1062

distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its super sturdiness and data security. The system of course also…

Details

D633-603B

additional software. The interface card can be configured redundantly (separated between each other Redundant basic unit pm802f) and can be plugged in and out and replaced online. Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd One PS can plug in…

Details

D633-599B

arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard) Interface. Basic characteristics: 1ee802.3 Ethernet standard o Ei801f provides 10base2 thin cable communication interface Ei802f provides 10BASE5 thick cable connection (through AUI interface) Ei803f provides 10Base-T…

Details

D633-525B

undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation.   The data communication between the field process controller PS. operating station 0s and the engineer station es is completed by the system network (diginets), which is inserted The – Ethernet network card on the PS basic unit provides the interface…

Details

D633-501B

25KBd Foundation Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS. Industrial “field control explosion (AC800F) consists of the following components: Basic unit pm802f Power supply sa801f/sd802f o Ethernet network card ei801f/ei802f/ei803f o Fieldbus interface card fi810f/fi820f/fi830f Various accessories…

Details

D633-481B

information from the bus. The interface card is easy to replace and plug and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at…