MMME162-413

controllers. Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured -Block fi810f…

Details

MMME162-412

fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the…

Details

MVME162-263

of Fieldbus interface card Support hot plug of Fieldbus interface card Technical indicators of basic unit pib02f: CPU :Intel 80960HT25/75 32-bit RISC superscalar processor with operation speed of 150 MIPS 4 MB FLASH-EPROM EEPROM,serial, 16 Kbit o Ram 8 MB (with error check and correction function, abb patent) 16 K internal cache (CPU cache RAM)…

Details

MVME162-23

and the second network cards can be interconnected with each other to form a special Redundant communication link (diginetr) to ensure information synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation.…

Details

MVME162-223

FM class 1 div2, ghost, Lloyd Installation area: Class 1 div 2 The PS supports the following types of fieldbus standards: Profibus DP,up to 12 MBd Modbus RTU,1200 to 38. 4KBd Industrial” CAN I/0 Bus o Open CAN -Bus,up to 1 MBd o Foundation Fieldbus H1 up to 31. 25KBd Foundation Fieldbus H2 (fast Ethernet)…

Details

MVME162-222

communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is easy to replace and plug and…

Details

MVME162-202

distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network topology can be selected for the…

Details

MVME162-201

The system scale has strong scalability. The single system supports 1 to 100 control stations and 100 operation stations at most. Each control The station can support thousands of i/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is all metal enclosure, which…

Details

MVME162-032

optical fiber) and network topology structure according to the actual situation of the application. Popular PC and MS_ Wi ndows2000 has been widely used in various fields all over the world and has become the de facto standard computer platform Set. The operating station 0s, engineer station es and data gateway GS of the industrial…

Details

MMME162-020A

Can (operate and display, print, trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems Yes. The process control level realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control Control, sequence control and batch intermittent control functions. The internal communication of the…

Details