TRICONEX TRICON 4609

de facto standard computer platform. tower. The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform to ensure the system’s Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance. System engineering is very convenient. The configuration language is…

Details

TRICONEX TRICON 4409

operation is realized by two redundant field controllers. Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller…

Details

TRICONEX TRICON 3007

replacement card fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed…

Details

TRICONEX TRICON 4329

CPU :Intel 80960HT25/75 32-bit RISC superscalar processor with operation speed of 150 MIPS 4 MB FLASH-EPROM EEPROM,serial, 16 Kbit o Ram 8 MB (with error check and correction function, abb patent) 16 K internal cache (CPU cache RAM) Ram backup battery (matchdog, optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required…

Details

TRICONEX TRICON 3006

slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation.   The data communication between the field process controller PS. operating station 0s and the engineer station es is completed by the system network (diginets), which is inserted The – Ethernet network card on the PS…

Details

TRICONEX TRICON 4351B

(AC800F) consists of the following components: Basic unit pm802f Power supply sa801f/sd802f o Ethernet network card ei801f/ei802f/ei803f o Fieldbus interface card fi810f/fi820f/fi830f Various accessories The main components of the field controller PS are described below. Basic unit pm802f The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans…

Details

TRICONEX TRICON 4119

has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the same tool CBF (control build f) software for configuration, debugging and diagnosis mouth Access to all information from the site,…

Details

TRICONEX TRICON 4118

function blocks from practical engineering applications are also expanded. Any complex control All schemes can be realized by the combination of these function blocks. The function blocks provided by the system mainly fall into the following categories: o Analog quantity processing o Digital quantity processing Loop adjustment Logical sequence control c Logical operation Monitoring function…

Details

TRICONEX TRICON 4108

supports PROFIBUS, FF, MODBUS, can and other countries International standard fieldbus, PROFIBUS is the most widely used open fieldbus international standard in the world, which is divided into FMS, DP and pa Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other…

Details

TRICONEX TRICON 8310

configuration modes. The system contains about 220 functions The algorithm library of energy block, the basic library with more than 200 graphic symbols and the extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete the configuration and commissioning of process level, operation level…

Details