VE4016

Information) system pioneered and led by ABB in technology. information technology) new trends. The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is realized function (operation and display, printing, trend display and alarm), and also complete…

Details

VE4015

maintaining this market position is the quality of our products quantity, and quality from manufacture all the way to service. ABB automation early In 1990, it obtained the DQS certificate based on ISO9001 certification, EQnet quality based on ISO 9000/EN 29000 was subsequently achieved Certification. However, the Freelance 800F is more than technical excellence, I…

Details

VE4014

transmission medium such as AUI, twisted pair, fiber optic or coaxial cable. Freelance OPC server for connecting to higher-level operators station (800xA) or other OPC client. Freelance Control System Real-time process values ??and alarms in the system can be accessed via OPC. We also provide a C language programming interface to embed external In Windows…

Details

VE4013S2B2

Controller executes open loop and closed loop control function. Freelance 800F DigiVis Operator Level DigiVis operator stations use PC hardware, either standard commercial Business PCs can also be industrial-grade PCs and run on Micro- under soft Windows operating system. DigiVis supports dual-screen display operation operating technology, that is to say, two operations can be performed…

Details

VE4013S2B1

Automatic generation of global data between the process control station and the operator station According to communication.   For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment in establishing data communication and interactive access. And ensure the consistency…

Details

VE4013S1B2

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

Details

VE4013S1B1

temperature…60 C, with automatic temperature monitoring o EMC (Electromagnetic Compatibility) according to EN50082 mouth Certifications: CE, NAMUR, CSA, CSA-NRT More about this source textSource text required for additional translation information Send feedback 5,000 character limit. Use the arrows to translate more.

Details

VE4012S2B2

modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control The scheme can be realized by the combination of these function blocks. The function blocks provided…

Details

VE4012S2B1

controller supports Profibus, FF, ModBus, Can, etc. International standard fieldbus, Profibus is the most widely used open fieldbus international standard in the world, divided into FMS, DP and PA Level 3, DP communication rate can be as high as 12Mb. Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus…

Details

VE4011B2

configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram (LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions Algorithm library for energy blocks and a basic library with more than 200 graphic symbols and…

Details