VE4002S1T2B1

protocol equipment. The maximum transmission rate is 38.4kbd and can be configured. Its Standards Association Modbus Different physical interfaces can be selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation Away. And the redundant operation is realized by two redundant field controllers. Fi8i0f card is a triple can bus protocol interface…

Details

VE63006

(processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard) Interface.   Basic characteristics: 1ee802.3 Ethernet standard o Ei801f provides 10base2 thin cable communication interface Ei802f…

Details

VE4006P2

corresponding fieldbus actuator. Two field controllers can realize controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special Redundant communication…

Details

VE6101

interface card is easy to replace and plug and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12…

Details

VE6101

stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network topology can be selected for the system bus…

Details

VE4001S2T2B1

sequential function diagram (SFC), structured text (st) and other graphical configuration modes. The system contains about 220 functions The algorithm library of energy block, the basic library with more than 200 graphic symbols and the extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to…

Details

VE4003S2B1

various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between the controller and various intelligent devices such as i/0 or field instruments) adopts the international standard field general Line. The field controller supports…

Details

VE4005S2B1

display, print, trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems Yes. The process control level realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control Control, sequence control and batch intermittent control functions. The internal communication of the process control station…

Details

VE4032S1T2B1

intermittent control functions. The internal communication of the process control station (between the controller and various intelligent devices such as I/0 or field instruments) adopts the international standard field controller. Wire. The field controller supports various field buses such as Profibus. Profibus is the most widely used open field bus in the world. Line international…

Details

VE4003S5B1

integrates the advantages of traditional DCS and PLC in one body and supports a variety of international field bus standards. It has both the complex analog loop regulation capability of DCS Power-friendly human-machine interface (HMI) and convenient engineering software, and at the same time have high-speed logic and sequence control equivalent to high-end PLC indicators.…

Details