CP415M

station (between the controller and various intelligent devices such as I/0 or field instruments) adopts the international standard field controller. Wire. The field controller supports various field buses such as Profibus. Profibus is the most widely used open field bus in the world. Line international standard, divided into FMS, DP 版权归千图网所有,盗图必究 Industrial “is a world…

Details

CP410M

convenient engineering software, and at the same time have high-speed logic and sequence control equivalent to high-end PLC indicators. control performance. The system can be connected to both conventional I/0 and various field bus devices such as Profibus, FF, CAN, and Modbus. system tool It has a high degree of flexibility and excellent scalability, whether…

Details

07SK50

archived or backed up. When programmed by the user, a list of variables and labels is automatically created. Moreover, both variables and process points can be opened and closed directly in FBD or IL Revise. List other features include: Project-wide modification of names, comments, data or module types ●Search and display based on specific criteria…

Details

AC31GRAF

Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field device via fieldbus ready. system communication Communication between operator level and process…

Details

XE08B5

Structured Text (ST) ●Extensive function block library, user-defined function blocks can also be added Added to it, the macro library and graphic symbols can be customized for the user. Blocks can create graphics and operator panels. ●Any standard can be integrated by means of GSD file import PROFIBUS-DP and PA devices, and through user-defined pairing…

Details

XO16N1

equipment (PROFIBUS, FOUNDATION Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station and the operator station According to communication.   For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment…

Details

XK08F1

Automatic generation of global data between the process control station and the operator station According to communication. For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment in establishing data communication and interactive access. And ensure the consistency of…

Details

XC08L1

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

Details

XO08Y1 DSC

divided into FMS, DP and PA Level 3, DP communication rate can be as high as 12Mb. Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus instruments. Communication between the process station, operator station and engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission…

Details

XO16N1 DSC

function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions Algorithm library for energy blocks and a basic library with more than 200 graphic symbols and an extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete…

Details