TRICON 4119

TRICON 4119 programming Think about lowering costs in the first place! This is what we developed the Freelance 800F system for: Keeping hardware prices consistent with those of programmable logic controllers In this way, cost efficiency can be improved by reducing user engineering costs. How the Freelance 800F process control system helps users reduce Low…

TrICoN 8312

TrICoN 8312 be mixed Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd) Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field including equipment management information Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage systems…

TrICON 4118

TrICON 4118 the system bus DigiNetS (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables and mixed media) and network topology can be selected for the system bus. Simple layout, due to the use of TCP/IP protocol, the system can also use the public telephone network (dial-up mode) or…

TRICON 8311

TRICON 8311 control The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is encapsulated in an all-metal shell, which can withstand the most Harsh industrial environment. The device can be installed either in a cabinet or on…

TRICON 4108

TRICON 4108supports Modbus. The communication with the intelligent field instrument is through IART protocol or field bus (31. 25Kb ProfibusPA and FF bus). The system communication between the operation management level and the process control level is realized by Di giNetS network (Industrial Ethernet/IEEE802.3 standard), Users can choose the communication transmission medium (ordinary cable or…

TRICON 8310

TRICON 8310 without additional software. The interface card can be configured redundantly (separated between each other Redundant basic unit pm802f) and can be plugged in and out and replaced online. Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd One PS…

TrICoN 7518-1

TrICoN 7518-1 FLASH-EPROM EEPROM,serial, 16 Kbit o Ram 8 MB (with error check and correction function, abb patent) 16 K internal cache (CPU cache RAM) Ram backup battery (matchdog, optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16 bit…

TRICON 8301A

are described below. Basic unit pm802f The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the The signals of the field bus sensors are processed according to the control application program configured by the user, and then the calculation results are passed The fieldbus…

TRICON 8300A

TRICON 8300A interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is easy to replace and plug and play (plug & play) and can be plugged in and out with power. The field controller PS has the…

TRICON 8302A

TRICON 8302A i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network topology can be selected for…